 +====== CRISP Ninja (Standalone CRISP GUI) ======
 +
 +CRISP Ninja is a standalone application that works with CRISP on both the ''Tiger/TG1000'' and ''MS2000'' controllers. 
 +
 +This is a Windows only application and works on Windows 10.
 +
 +**Download:**
 +  * [[http://www.asiimaging.com/downloads/software/CRISP_Ninja_04142022.zip | Latest build - April 2022]]
 +  * [[http://www.asiimaging.com/downloads/software/CRISP_NINJA_9282021.zip | Previous build - September 2021]]
 +  * [[http://www.asiimaging.com/downloads/software/CRISP_NINJA_4142020.zip | Previous build - April 2020]]
 +  * [[http://www.asiimaging.com/downloads/software/CRISP_NINJA_090919.zip| Previous build - September 2019]] 
 +  * [[http://www.asiimaging.com/downloads/software/crisp_ninja_march_2019.zip| Previous build - March 2019]]
 +
 +===== Using CRISP Ninja =====
 +
 +{{::crisp_ninja.jpg?direct |}}
 +
 +**1. COM Port** - RS232 serial communications port.
 +
 +**2. Baud Rate** - RS232 serial communications speed. [Always ''115200'' for ''TG1000'']
 +
 +**3. Poll Rate [ms]** - The delay between requesting the status of the CRISP device. Leave it at 120 ms, frequent polling may cause freezes.
 +
 +**4. Card Address** - The card address for ''TG1000'' systems. Leave this input blank for ''MS2000''.
 +
 +**5. Axis Character** - The axis that CRISP is using to auto-focus, usually Z or F.
 +
 +**6. Log Save Directory** - The save directory to log data if logging is enabled.
 +
 +**7. Find CRISP** - Queries the controller to automatically find the ''Axis Character'' and ''Card Address''
 +
 +**8. Start** - Connect to the controller, click again to disconnect.
 +
 +**9. Log Data** - Check this box to log data to the ''Log Save Directory''.
 +
 +**10. State** - The current state of the device.
 +
 +**11. Pos[um]** - The position of the axis in microns.
 +
 +**12. AGC** - The AGC value.
 +
 +**13. SNR** - The signal to noise ratio.
 +
 +**14. Idle** - Set the CRISP state to Idle.
 +
 +**15. Log Cal** - Set the CRISP state to Log Cal.
 +
 +**16. Dither** - Set the CRISP state to Dither.
 +
 +**17. Set Gain** - Set the CRISP state to Set Gain.
 +
 +**18. Lock** - Focus lock the device.
 +
 +**19. Unlock** - Unlock from focus lock.
 +
 +**20. Set Offset** - Zeros the error signal, CRISP will attempt to keep current focus. 
 +
 +**21. LED Intensity [%]** - Sets the IR LED intensity as a percentage of brightness.
 +
 +**22. Objective NA** - Set to the objective's numerical aperture.
 +
 +**23. Averaging** - Error signal averaging.
 +
 +**24. Loop Gain** - Adjust to change the responsiveness of CRISP.
 +
 +**25. Lock Range [mm]** - Prevent the axis from moving too far out of focus lock.
 +
 +**26. Update Rate [ms]** - The time in milliseconds to wait between updates to the CRISP trajectory.
 +
 +**28. Clear** - Clears the black text box of all previous entries.
 +
 +**29. Help** - Opens the default web browser and navigates to this page.
 +
 +Please refer to the [[https://www.asiimaging.com/docs/crisp_manual| CRISP manual]] for more detailed information.
 +