User Tools

Site Tools


stablestage

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
stablestage [2021/05/19 15:45] – created brandonstablestage [2021/09/23 17:15] (current) – external edit 127.0.0.1
Line 1: Line 1:
 +======= ASI Stable Stage =======
 +
 The ''ASI Stable Stage'' plugin can measure and correct thermal drift. The ''ASI Stable Stage'' plugin can measure and correct thermal drift.
  
 Requirements: ''Micro-Manager 2.0'' Requirements: ''Micro-Manager 2.0''
  
-Optional: ''CRISP'' or ''Autofocus3''+Optional: ''CRISP'' or ''Autofocus3'' (Note: ''Autofocus3'' integration coming soon) 
 + 
 +Send an email to ''brandon@asiimaging.com'' if you're interested in the plugin. 
 + 
 +==== Controls ==== 
 + 
 +{{:stablestage_maintab.png?direct|}} 
 + 
 +**Main Tab:** 
 + 
 +**1) Run Forever:** Check this box if you would like to run the test indefinitely in ''Drift Measurement'' or ''Stage Stabilization'' mode. 
 + 
 +**2) Test Length:** If you're not running the test indefinitely, then you can specify the number of minutes you would like the test to run. 
 + 
 +**3) Drift Error:** The amount of drift in microns required for ''Stage Stabilization'' to attempt to correct the XY stage position. 
 + 
 +**4) Max Move:** The maximum amount that ''Stage Stabilization'' will move the stage in microns. 
 + 
 +**5) Phase Correlation:** Which phase correlation algorithm to use for ''Stage Stabilization''
 + 
 +**6) Autofocus Device:** Which autofocus device to use for ''Stage Stabilization''. Select ''None'' if no device available. 
 + 
 +**7) XY Moves:** Invert the computed shift values in either the X or Y axes. 
 + 
 +**8) XY Gain:** A multiplier to adjust the computed shift value. 
 + 
 + 
 +{{:stablestage_cameratab.png?direct|}} 
 + 
 +**Camera Tab:** 
 + 
 +**1) Show Images:** Check this box to show the phase correlation comparison images while running the test. 
 + 
 +**2) Keep Shutter Open:** Keep the cameras shutter open during the test. 
 + 
 +**3) Capture Delay:** The number of milliseconds to delay between each phase correlation comparison test. 
 + 
 +**4) Downsample Factor:** The amount to downscale the camera images, this can increase performance significantly.  
 + 
 +**5) Apply Gaussian Blur:** Apply a blur filter to the captured images, this setting is recommended. 
 + 
 +**6) Blur Amount:** The amount of blur to apply to the images, the standard deviation of the Gaussian filter. 
 + 
 +**7) Use Background Subtraction:** Check this box if you want to use background subtraction. 
 + 
 +**8) Snap Background Image:** Snaps an image to use as the background subtraction image. 
 + 
 +**9) View Background Image:** Opens a frame to view the captured background subtraction image. 
 + 
 + 
 +{{:stablestage_datatab.png?direct|}} 
 + 
 +**Data Tab:** 
 + 
 +**1) Save Directory:** The directory to save the images into. 
 + 
 +**2) File Name:** The file name prefix to save the logging data. 
 + 
 +**3) Logging:** Check these boxes to log information about XY moves and Z moves. 
 + 
 +**4) Save Images:** Check this box to save images into the save directory. 
 + 
 +**5) Save Type:** The criteria for saving images, the spinners below control the options for save types. 
 + 
 +**6) Save Every N Images:** This is always save the first image, and then every N images afterward. 
 + 
 +**7) Move Threshold:** Save the test image a move command above a certain threshold is sent to the controller. 
 + 
 +**8) Correlation Threshold:** Save the test image if the correlation coefficient of the comparison is below this threshold.  
 + 
 +**9) Limit Save Data:** The maximum amount of image data to save in a test run in gigabytes. 
 + 
 +{{tag> software auto_track}} 
Address: 29391 W Enid Rd. Eugene, OR 97402, USA | Phone: +1 (541) 461-8181